EN



  • 名称:紧缓冲耐火光缆

    工作波长
    模式场直径
    包层直径
    涂层直径

  • 产品参数:



    Fiber Parameters

    No.

    Items

    Unit

    Specification

    SM

    1

    Operating wavelength

    nm

    1310

    nm

    1550

    nm

    1625

    2

    Mode Field Diameter

    1310nm

    μm

    (8.6~8.8)±0.4

    1550nm

    μm

    9.8±0.5

    3

    Cladding Diameter

    μm

    125±0.7

    4

    Coating Diameter

    μm

    245±7

    5

    Max attenuation Tight buffer

    1310nm

    dB/km

    ≤0.4

    1550nm

    dB/km

    ≤0.3

    6

    Max attenuation Loose tube

    1310nm

    dB/km

    ≤0.37

    1550nm

    dB/km

    ≤0.22

    1625nm

    dB/km

    ≤0.25


    No.

    Items

    unit

    Specification

    OM1

    OM2

    OM3

    OM4

    1

    Operating wavelength

    nm

    850

    nm

    1300

    2

    Core Diameter

    μm

    62.5±2.5

    50±2.5

    50±2.5

    50±2.5

    3

    Cladding Diameter

    μm

    125±2

    125±1

    125±1

    125±1

    4

    Coating Diameter

    μm

    245±10

    242±7

    242±7

    242±7

    5

    Max attenuation Tight buffer

    850nm

    dB/km

    3.5

    3.5

    3.5

    3.5

    1300nm

    dB/km

    1.5

    1.2

    1.2

    1.2

    6

    Max attenuation Loose tube

    850nm

    dB/km

    3.2

    2.8

    2.8

    2.8

    1300nm

    dB/km

    1.0

    0.9

    0.9

    0.9


    Cable Parameters

    Items

    Specifications

    Fiber Count

    4

    Tight-buffered Fiber

    Dimension

    850±50μm

    Material

    PA/Hytrel/LSZH

    Color

    Blue、Orange、Green、Brown

    Strength MemberⅠ

    Specifications

    6*1580D

    Material

    Aramid Yarn

    Strength MemberⅡ

    Dimension

    0.5mm

    Material

    FRP

    Inner Jacket

    Dimension

    4.7±0.1mm

    Thickness

    SHF1/SHF2/SHF2

    Color

    Black

    MetallicArmor

    Material

    Galvanized Steel Wire

    Diameter of wire

    0.2mm

    Coverage

    85% Min.85%

    Outer Jacket

    Dimension

    7.6±0.2mm

    Material

    SHF1/SHF2/SHF2

    Color

    MM Orange

    SM Yellow


    Mechanical and Environmental Characteristics

    Items

    Unite

    Specifications

    Tension(Long Term)

    N

    300

    Tension(Short Term)

    N

    600

    Crush(Long Term)

    N/10cm

    300

    Crush(Short Term)

    N/10cm

    1000

    Min. Bend Radius(Dynamic)

    mm

    20D

    Min. Bend Radius(Static)

    mm

    10D

    Installation Temperature

    -10~+60

    Operating Temperature

    -10~+70

    Storage Temperature

    -20~+70


    1.光缆机械性能

    1)拉伸强度

    测试方法:IEC 60794-1-2 E1

    测试长度:≥50m

    卡盘直径:250mm

    拉伸速度:10mm / min

    拉伸负荷:长期300N;短期600N

    测试条件:短期加载时间:30分钟;短期加载时间:5分钟

    验收标准:单模最小变化小于0.2dB;多模模具最小变化小于0.3dB



    2)壁球

    测试方法:IEC 60794-1-2 E3

    测试条件:1000 N / 10cm,持续1分钟

    验收标准:单模变化小于0.2dB;多模模具变化小于0.3dB

    没有护套破裂和纤维破裂



    3)影响

    测试方法:IEC 60794-1-2 E4

    锤高:150mm

    冲击重量:20N

    冲击重量:3倍,每个冲击点的间距

    单模变化小于0.2dB;多模变化小于0.3dB



    4)反复弯曲

    测试方法:IEC 60794-1-2 E6

    卡盘直径:200mm

    弯曲次数:1000次

    验收标准:单模小于0.2 dB;多模模式小于0.3 dB



    5)缠绕

    测试方法:IEC 60794-1-2 E8

    循环时间:1000

    加载速度:周期/分钟

    轮径:100mm

    加载:40N

    验收标准:单模变化小于0.2dB;多模模式变化小于0.3dB



    2.光缆环境性能

    1)温度衰减特性

    测试方法:IEC 60794-1-2 F1

    测试温度:低温-20℃,高温+ 70℃

    每个温度保持时间8h

    循环时间:2

    接受标准:单模变化小于0.3dB;多模模式变化小于0.5dB

    2)燃烧性能

    耐火性:IEC 60331-25

    耐燃性:IEC 60332-1-2

    扩散趋势:IEC 60332-3-22

    卤素含量:IEC 60754-1

    烟雾密度:IEC 61034-2



    3.光缆识别

    外护套标有黑色标识,间隔为1m,标识如下,其他信息可根据客户要求提供

    1)光缆类型和芯数

    2)制造名称

    3)制造年份

    4)长度识别